October 2, 2026GoogleI contracted with Nexus Energy Systems for a residential solar and battery storage system totaling over $50,000, with contract terms explicitly specifying that the battery system would operate in "Self Consumption & Savings Mode" to offset household power usage at night.The installation was left materially incomplete. Approved engineering plans (Sheet PV-4) require consumption metering Current Transformers (CTs) installed on the main utility service conductors. Nexus completed their work without installing these clamps, and their own installation photo records confirm that consumption meter terminals C1 and C2 inside the Enphase IQ Gateway combiner were left completely unwired. Because these physical sensors were omitted, the battery system cannot measure home energy usage and cannot function in the contracted self-consumption mode. Independent remote diagnostics conducted by Enphase Energy Technical Support confirmed that whole-home consumption drops to 0.00 kW when solar generation stops and verified that the battery cannot operate as intended until an installer physically wires the consumption meters. I contacted Nexus management on September 28 and October 1, 2026, providing specific references to their own closeout photos showing the omitted hardware and requesting an on-site technician to complete the wiring. Instead of scheduling remediation, Director of Operations Jesse Garay refused to send a technician, erroneously asserting that AC line voltage wiring constituted metering and stating that the system was operating as it should. Nexus has collected tens of thousands of dollars while leaving contracted, approved hardware uninstalled, rendering the battery storage system non-functional for home offset. Due to their written refusal to complete the physical installation, this matter has been escalated to the California State Contractors License Board (CSLB). I strongly caution consumers against using this company
The business replied on Google · October 13, 2026
Mr. Rivas - You posted this review within 48 hours of contacting us. We reached out IMMEDIATELY and shared both your agreement and photos of the CTs installed and showed you the installation was not material incomplete. In fact - batteries cannot function without the CTs. They are installed in 2 separate locations as the photos showed. We went on to share the Enphase Guidelines for CT installation directly from the manufacturer along side your current configuration. In addition and most important regarding lack of backup capability- as we discussed with you, you were fully aware that your batteries do not have backup capability under the current configuration, although Nexus does offer backup it was not chosen a year and a half ago. On page 1 of your agreement/contract with Nexus it states in bold “GRID TIED BATTERY ONLY - NO BACKUP MODE OR BACKUP CAPABILITY-SELF CONSUMPTION & SAVINGS MODE ONLY WILL BE AVAILABLE.” - We would love a chance to send a tech to troubleshoot any issues you are having but have not been able to convince you to accept service as mentioned. We believe this complaint is a mis characterization of what has occured as we have also pointed out here in this response and via email and have been unwilling to acknowledge any of the evidence we have provided to you or engage futher, which we believe is not fair if there is a mis communication or technical issue that we are more than willing to help resolve. We are ALWAYS her to help our customers and offer lighting fast tech support to work through any issues! We also greatly appreciate your business are are here to serve when you decide to re engage! Regarding the potential Service visit - There are slight abnormalities on the consumption monitoring which we are more than willing to field in a service call. You also have the power within your ENPHASE app to change the battery profile as you see fit. Menu —> settings —> profile. You absolutely have the power to toggle between AI optimization and Self consumption mode. You currently have that capability with no additional CTs (beyond the ones installed) which are needed. Regarding the location of your CTs - terminals C1 and C2 are default configuration terminals. There was no CT wiring called out on your plan set. Enphase has separate configurations for different system setups, and in your case, you had an existing Franklin battery & solar system. We did a system addition which required an alternate CT configuration but we can triple confirm all of the items that we have said previously. We appreciate your business and remain open to helping if you are willing to engage our service team!