Rain Prize
April 27, 2026GoogleI had a bad experience but i have faith this Company can do better in the future. They installed an atmospheric rheem hot water heater and a HE allied air furnace with a crew of 4 or 5 guys in under 8 hours. The water heater had 2x gas leaks on the section of line they worked on and columbia had to shut us off and we had to wait but aviles never came so the columbia program we signed up for called someone else to fix the leak after no one showed up for 2 weeks. The furnace they installed had a huge 1 inch gap on 2 sides of the blower cabinet bottom plate so the blower was pulling basement air within feet of the gas water heater. Ended up getting backdrafting issues and CO readings on our meter until we figured it out and sealed the cabinet. The cabinet gap was the result.of poor manufacturing of the stamped metal. Not Aviles fault. But their crew overlooked that and neglected to apply mastic or hvac tape to fix this simple problem. There was a large gas leak on the line to the furnace as well after their work. They must not use a gas sniffer to test their work. They used schedule 40 DWV pipe to build the furnace exhaust linetl thru the wall. This is not allowed by code. It should have been schedule 40 solid wall/ non cell core, rated for pressure. ***almost certain*** . The chimney liner they installed for the hot water tank was uninsulated, in a cold exterior chimney. i quit calling them after they expressed their unhappiness at driving 65 miles for service calls. They came several times when i was trying to figure out why the furnace was shutting itself off(eventually figured out it was backdrsfting the water heater). They couldnt figure it out and expressed their unhappiness at driving so far for no reason. i had to end up calling other companies to service the unit. Many of them told me to call the installer instead. Grid lock. The chimney liner they installed failed after 3.5 years. Exhaust fumes quit making it all the way up all the time. 40 ft chimney , 4 inch liner, cold.chimney, uninsulated.Pretty sure code recommends insulated liner in this situation and sometimes 5 inch flue for this tall of a chimney so flue gasses can escape before cooling too much. Went w an electric unit as new liner and insulation was going to be 1000 plus. Their crew gets 2 stars instead of 1 because at the time, no one else wanted to take the job ... a free program thru columbia gas for low income families. And they got use heat during winter . However i would never call this company for anything. I emailed the company about these issues as their phone was down at the time i called. No one responded.
The business replied on Google · September 22, 2026
I would love to identify you as a customer but I can't find any record of you and you speak like a industry insider. But just in case Columbia Gas approved every job done in that program so any job would have been monitored by a 3rd party. I dont think you are real but please call me if you are